Showing posts with label Vent. Show all posts
Showing posts with label Vent. Show all posts

2.3 Locating Inlet Vents and Cross Vents as a Noise Control Measure

Locating Air Inlet Vents
The orientation of a building has a significant impact upon noise levels at the different facades of the building. It is often the case that facades on the opposite side of a building to a significant noise source will be considerably lower than those on the noisy side of the building.
By orientating the building and by placing non-critical spaces on the noisy side of a building, it is possible to form a good acoustic buffer. In these instances, cross vent can be used where the air intake is placed on the quiet side of the building. Cross ventilation to an atrium or circulation zone is then used to provide the air extract. Alternatively, single sided ventilation could be used for sensitive spaces on the quiet side of a building.
1 shows sound levels around a building in the form of a noise map. The classroom on the far side of building to the A40 are vented using openable windows.


1
Cross Vent to Assist with the Prevention of Noise Break-in
In instances where a building is located on an exceptionally noisy site, cross ventilation can improve the feasibility of natural ventilation. Cross ventilation has an important advantage over single sided ventilation, in that air inlet vents can be between 25% to 75% smaller than those required for single sided ventilation. This significant reduction in vent size helps considerably in preventing noise break-in, as smaller vents restrict the passage of sound into a building.

2.4 Bench Seating

Adding attenuation to the vented facade of a single storey building is comparatively easier than a multistory building, since it is often possible to extend the building envelope, accommodating the additional depth of the NAT Vent Boxes.

In the case of single storey buildings, it is common to maintain a simple vertical thermal line, by placing the thermal damper into the line of the facade 4. The acoustic attenuation in this instance is placed on the external side of the building. This design approach has been implemented by MACH Acoustics on several projects.

The NAT Vent Box has been installed under bench seating, flower boxes, play boxes, small steps in the facade and other elements. These units have all been used to hide and accommodate the additional facade depth often required when naturally ventilating a building on a particularly noisy site.

A second advantage of single storey buildings is the potential to incorporate the NAT Vent Box above or within roof lines, above corridors, over storage rooms and other areas.

1.3 Acoustics and Cross Ventilation

It is generally accepted that cross ventilation is the most effective form of natural ventilation. Acoustics plays a key role in the design of a cross ventilated building as air must flow freely through the building whilst maintaining privacy across partitions. To allow cross ventilation and maintain privacy, cross talk attenuators are required within partitions adjacent to circulation spaces.

One of the key design benefits of the NAT Vent Attenuator is the simple implementation of cross ventilation through a corridor wall, while still maintaining the acoustic integrity of these partitions. Furthermore, this product enables cross ventilation to vertically stacked rooms, vented through a single stack. In other words, vertically stacked spaces no longer require independent chimneys to maintain the acoustic separation between rooms, resulting in a significant recovery of floor area and a considerable cost saving.

One of the drawbacks of ventilating through the corridor wall is the requirement for an exceptionally large bulk head, such to accommodate large, heavy attenuators. The NAT Vent has been designed to provide exceptional levels of cross talk separation. MACH Acoustics has undertaken extensive research to understand the required levels of acoustic separation across these partitions. Depending upon the air flow and the required level of acoustic separation, the NAT Vent can be as slim as 600mm deep. In some instances, this is required to be increased to 1200mm, depending on the required acoustic performance.


To visit the MACH Blog